Kerick Ventil MA052 PVC Mini Schwemmventil, Tank Mount, Upassbar Arm, 1,5 gpm bei 60 psi, 1/2 NPT Männlech

Brand:Kerick Valve

3.4/5

26.84

Dëse Kerick MA052 Schwämmventil ass en Tank-Mount Stil mat engem justierbarem Aarm, an ass aus PVC mat 18-8 Edelstahl Hardware gemaach. De Ventil huet eng 0,093 Ouverture a säi geschätzte Flowrate ass 1,3 Gallonen pro Minutt (gpm) bei 40 Pond pro Quadrat Zoll (psi) an 1,5 gpm bei 60 psi. De Ventil-Inlet huet 1/2 NPT männlech verlängert Fuedem mat enger Dichtungswäscher a Spuermutter fir duerch eng Tankwand ze montéieren, an de Ventiloutlet ass fräi fléissend. De Ventil ass aus der National Sanitation Foundation (NSF) guttgeheescht PVC (Polyvinylchlorid) gemaach, seng ersatzbar Dichtungen sinn aus TPE (thermoplastesche Elastomer) fir Haltbarkeet a chemesch Resistenz gemaach, a seng Hardware ass aus 18-8 Edelstol fir Korrosiounsbeständegkeet. De Ventil huet e 1,5 Duerchmiesser a 4 laange Polyethylen-Schwemmen, déi un den justierbare Schlosshebelarm verbonne sinn. Dëse Floatventil ass gëeegent fir an enger Vielfalt vun Uwendungen ze benotzen, wéi zum Beispill Sprangbueren a Béischtenwassertanken. Floatventile benotzen eng Staang a Schwämmkugel, déi un engem Ventil-Ausschalthebel befestegt ass, fir de Flux an oder aus engem Tank ze kontrolléieren. De Floatball klëmmt oder fällt mam Niveau vun der Flëssegkeet am Tank, ännert de Wénkel vum Ventil-Ausschalthebel. Wann de Wénkel vum Ventil Hiewel genuch ännert, mécht de Ventil op oder zou. Floatventile ginn no dem Volume vun der Flëssegkeet bewäert, déi duerch si bei engem bestëmmten Drock fléisse kënnen, fir sécherzestellen, datt den Tank sou séier wéi en eidel kann opfëllen. D'Material aus deem e Schwämmventil konstruéiert ass muss gëeegent sinn fir d'Flëssegkeet an där se funktionnéiert, déi korrosiv oder bei enger extremer Temperatur ka sinn. Floatventile ginn benotzt fir automatesch den Niveau vun der Flëssegkeet bannent Panzer an enger Rei vun Uwendungen ze regléieren, wéi Sprangbueren, Béischtenwasserbehälter, Killtuerm a chemesch Fabrikatiounsanlagen. Kerick Valve fabrizéiert Flëssegkeetsniveau Kontrollventile fir industriell Uwendungen. D'Firma, gegrënnt an 1994, huet säi Sëtz zu Jacksonville, FL.WAT ASS AN DER BOX? * MA052 Krunn * PF154 Schwämm Kugel

1/2 NPT männlech threaded Inlet a Free-Flow Outlet. Bemierkung: MA052 huet en 1/2 NPT Pipe thread. Dëst ass extrem heefeg an der Sanitärwelt. De Fuedem moosst ongeféier 3/4 Zoll Duerchmiesser, dëst ass e gemeinsame Feeler fir déi, déi net mat Päiffäegkeeten a Sanitär kennen. Tankmontage mat erweiderten Fuedem op der Inletsäit vum Ventil fir duerch Tankmauer ze montéieren. PVC fir corrosion Resistenz. Geschätzte Flowrate bis zu 1,5 gpm bei 60 psi.
Brand Kerick Valve
Country of Origin USA
Domestic Shipping Item can be shipped within U.S.
Exterior Finish Stainless Steel
Inlet Connection Size .5 Inches
Inlet Connection Type National Pipe Tapered
International Shipping This item can be shipped to select countries outside of the U.S.
Is Discontinued By Manufacturer No
Item Dimensions LxWxH 7.5 x 2 x 3.3 inches
Item model number MA052
Manufacturer Kerick Valve
Material PVC
Outlet Connection Type MNPT
Product Dimensions 7.5 x 2 x 3.3 inches; 1.6 Ounces
Specification Met NSF

3.4

9 Review
5 Star
66
4 Star
17
3 Star
9
2 Star
3
1 Star
5

Schreift Är Bewäertung

Är E-Mail gëtt net publizéiert. All obligatoresch Felder sinn markéiert mat*

Scritto da: Ryan Kamba
Works - but for how long
This is the second one I bought. They last for about 6 months. Then they get stuck in the closed position. Going a different route next time.
Scritto da: Thomas C.
Size misleading
Too small
Scritto da: J.B. Cabell
Excellent value
This thing is much smaller than I had pictured in my mind. The whole assembly is barely longer than my open hand, so it can fit into tight spaces for a fountain project, or in a sump to maintain water level in a swimming pool. The description here at Amazon.com is nonsense, giving its length as 1 inch: The actual overall length is about 7.5 inches, or 6.5 inches from the mounting flange to the tip of the float, worst case. (See the second vendor-supplied image with the valve photographed against an inch grid for a better understanding of its actual size.) With allowance for installation and adjustment, the valve could be squeezed into a space as small as 8 inches by 2 inches. If installed in a bulkhead, the mounting surface should be flat and no thicker than about 0.25 inch, to allow enough thread protrusion on the outside to attach a threaded pipe fitting. Bulkhead mounting is optional: The male pipe thread on the valve is slightly tapered and can be screwed into any female pipe thread fitting, using Teflon tape on the threads for a watertight seal I gauged the valve orifice with a drill rod at 0.094 inch (3/32 inch) diameter, which accounts for the low flow rate specification. You may not want to fill a swimming pool with it from scratch, but for a typical backyard pool it will allow more than enough water to flow to compensate for evaporation loss. The float arm pivots on a stainless steel cotter pin, so it could easily be disassembled, should the need arise, although at the low cost of the assembly it may be more economical to replace it entirely. Depending on the placement of the valve, the float can be adjusted over a liquid level range of at least 4 inches, possibly as much as 6 inches, by loosening the stainless steel wing nut. One of these valves was successfully used to maintain the water level in a neighbor's swimming pool last summer during a month-long absence. See the customer photo that I posted, showing the minimalist installation with a few pieces of PVC plastic plumbing, an ordinary brick and a garden hose. The only problem I encountered was the hose of the automatic pool sweep once getting hung up on the valve, keeping it open continuously. Because of the restricted flow, no flooding occurred by the time I discovered the problem the next day. If I use it next summer again, I'll mount the valve with some sort of bumper or "fence" around it to keep the pool sweep hose clear, and I'll replace the leaky plastic hose fitting with a sturdier brass fitting.
Scritto da: William D Jamison
Works as Intended
This was easy to install and I use it in a backyard water feature. It has a 1/2" intake and seals well when full.
Scritto da: dreamer
Good valve when working, but 4 of them have failed after about 6 months.
The valves last welll for months, but then the seal, a 1/4" white plastic, nail-shaped part, is prone to internal bubbles full of water, which make the valves suddenly begin to leak badly, wasting water. The seals are difficult to replace down in our swimming pool filler sump, so I replace the whole valve. ...but proper molding by the manufacturer would have been much better. They the seals appear to have been molded with air bubbles, which eventually fill with water under pressure, so the seal grows a flexible lump. ...which you can break with a pin, and water comes out. I would replace with different brand, but all these small valves seem to have the same form. ...appear to be made, maybe, by the same maker.
Scritto da: Consumer Folk
Worked Perfectly in Fountain Setup. Excellent Sizing Guidance on Product Page
Bought as a replacement valve. As a non-plumber, I greatly appreciated the product description and picture showing the actual size for the item (the thread is about 3/4", but matches the 1/2" NPT standard). Once installed, this new valve immediately stopped the leak that I had with the original valve.
Scritto da: Salvador
Reliable and cheap.
My supply pipe coming out of the pool, flush on the wall tiles is 1/2". So I buy a 1/2" barb fitting male NPT, 70 cents lowe's. Soften the barb fitting on a trial scrap 1/2" pipe to reduce the barb diameter, or you can sand the barb with drill chuck to the id of barb fitting, around .010 bigger over the 1/2" pipe ID. (Do Not Drill the pool pipe ID to make it bigger, you need a smooth weld when you apply a primer and glue on pipe for water pressure application integrity, wait about 2 hrs. Connect a 1/2" elbow then the kerick valve, so the whole unit is parallel to the wall of the pool for less obstruction. I have it installed for about a 2 weeks now, set about halfway or middle of the mouth of the skimmer, with stable height the whole two weeks. Usually my pool go down 1/2" every 2 days, then I fill it up, about 30-45 minutes with timer, until the middle of mouth of skimmer. The water ball valve on the faucet is set on the low opening to avoid overfill just in case this kerrick valve malfunction. The thread on this is not a standard 1/2" NPT, but that 2 turn is enough, with the help of a provided nut, no leak, so no problem for me.
Scritto da: Tony Thiel
Does what I wanted it to do.
I wanted a water holding tank and used a 20 gallon Husky Garbage can, mounted this on it and it works just fine. I use the water with a very weak solution of fertilizer to water my 80 plus orchids and other plants. I had to use a couple of sturdy plastic plates to solidify the installation because the weight of the hose would buckle the area where it's mounted. But once that was done, it works just fine. October 28th, 2015 addendum: I think that something like this would also work great for adding water to an aquarium or fish tank. If the water coming out of your tap is chlorinated, letting it sit for a while will help dissipate the chlorine. This could also work as an emergency self filling water tank. Here in Hawaii, we are constantly warned about the possibility of a hurricane. A 33 gallon CLEAN garbage can filled with water would certainly help in an emergency. Just leave the cover on to keep dust and debris from getting into it. Actually, if you think hard enough, there are a lot of possibilities with this.
Scritto da: dave
Awesome
Awesome

Zesummenhang Produiten

Entdeckt eisen internationale Netzwierk

Mir schécken an 28 Länner, iwwer 200.000 Produkter. Bleift aktualiséiert, abonnéiert Iech op den Newsletter.

Array